Hire fleet
Hydraulic equipment for hire, much of it designed and built in-house
ITC offers a broad range of rental solutions for all sectors including Oil and Gas, Renewables, and Decommissioning. With a proven track record, our extensive offering covers hydraulic power units (HPU), reelers, flushing, filtration and transfer units, shears, grabs, overboard chutes, testing and control equipment to name a few.
Numerous units across fifteen categories, based on proven engineering and bespoke in-house designs, all meeting the demands of rigorous onshore, offshore, back deck and subsea applications, with ATEX Zone 1 and Zone 2 rated units in the fleet. Safety, versatility, and performance optimisation are at the forefront of every product we deliver.
We provide robust support for our rental fleet through comprehensive backups, spares packages and experienced personnel, ensuring your projects are completed successfully. Every unit is maintained by our own time served technicians and fully function tested before it leaves. Our trademarked products, like the Combi-Reeler® and OilArmour®, demonstrate our continuous commitment to innovating new subsea and offshore technologies.
Explore our full range of equipment via the category tabs to find the right fit for your project, or tell us what the job is and we will recommend the right unit.

Winch and reeler packages outside our workshop.
COMBI REELER®
Our own combined hydraulic power unit and umbilical reeler, built into a single skid. It halves the deck footprint of a separately skidded system, removes the safety hazard of interconnecting hoses and cuts the manpower needed to run it. Twelve units, including twin-pump sets for higher flow. They run 18.5kW to 55kW, up to 420 bar peak and 285 L/min, on drums of 200 to 300 metres.

An electric hydraulic combi-reeler from the hire fleet.
| DOWNLOADABLE SPEC PDF | POWER | ZONE | WORKING PRESSURE | MAX FLOW RATE | DRUM CAPACITY |
|---|---|---|---|---|---|
| HHR010C ⬇ | 22kW @ 50Hz | 25.3kW @ 60Hz | Safe Area | Nominal: 320 bar | Peak: 350 bar | 80 L/min @ 60Hz | 200m |
| HHR020C ⬇ | 22kW @ 50Hz | 25.3kW @ 60Hz | Safe Area | Nominal: 350 bar | Peak: 420 bar | 81 L/min @ 60Hz | 240m |
| HHR030C ⬇ | 22kW @ 50Hz | 25.3kW @ 60Hz | Safe Area | Nominal: 280 bar | Peak: 350 bar | 79 L/min @ 60Hz | 240m |
| HHR040C ⬇ | 55kW @ 50Hz | 66kW @ 60Hz | Safe Area | Nominal: 320 bar | Peak: 350 bar | 142 L/min + 28 L/min @ 60Hz | 300m |
| HHR050C ⬇ | 30kW @ 50Hz | 36kW @ 60Hz | Safe Area | Nominal: 320 bar | Peak: 350 bar | 78 L/min + 24 L/min @ 60Hz | 240m |
| HHR060C ⬇ | 30kW @ 50Hz | 36kW @ 60Hz | Safe Area | Nominal: 320 bar | Peak: 350 bar | 78 L/min @ 60Hz | 240m |
| HHR070C ⬇ | 55kW @ 50Hz (x2) | 66kW @ 60Hz (x2) | Safe Area | Nominal: 320 bar | Peak: 350 bar | 285 L/min + 37 L/min @ 60Hz | 300m |
| HHR080C ⬇ | 37.5kW @ 50Hz (x2) | 44.4kW @ 60Hz (x2) | Safe Area | Nominal: 320 bar | Peak: 350 bar | 284 L/min + 37 L/min @ 60Hz | 300m |
| HHR090C ⬇ | 55kW @ 50Hz (x2) | 66kW @ 60Hz (x2) | Safe Area | Nominal: 320 bar | Peak: 350 bar | 285 L/min + 37 L/min @ 60Hz | 300m |
| HHR100C ⬇ | 37.5kW @ 50Hz (x2) | 44.4kW @ 60Hz (x2) | Safe Area | Nominal: 320 bar | Peak: 350 bar | 284 L/min + 37 L/min @ 60Hz | 300m |
| HHR110C ⬇ | 18.5kW @ 50Hz | 22.2kW @ 60Hz | Safe Area | 250 bar | 43.8 L/min @ 60Hz | 240m |
| HHR120C ⬇ | 18.5kW @ 50Hz | 22.2kW @ 60Hz | Safe Area | 250 bar | 43.8 L/min @ 60Hz | 240m |
OILARMOUR®
Our own subsea multifunctional manifold, available in two-way, three-way and seven-way configurations. Rated to 350 bar.

OilArmour® subsea multifunctional manifold, all three configurations.
| DOWNLOADABLE SPEC PDF | DESCRIPTION | ZONE | WORKING PRESSURE | DIMENSIONS (ØxH) |
|---|---|---|---|---|
| OA ⬇ | Subsea Multifunctional Manifold | n/a | 350 bar | 2-Way: 200mm × 380mm 3-Way: 200mm × 380mm 7-Way: 290mm × 380mm |
HPU'S
The largest part of the fleet, and the part most jobs start with. Air-driven, electric and diesel driven power units, from a 2.8 L/min air-driven unit up to a 126kW diesel delivering 286 L/min. Both ATEX Zone 1 and Zone 2 rated units are available alongside the safe area machines, at 150 to 400 bar nominal and 420 bar peak.

An electric hydraulic power unit from the hire fleet.
| DOWNLOADABLE SPEC PDF | POWER | ZONE | WORKING PRESSURE | MAX FLOW RATE |
|---|---|---|---|---|
| AHPU003 ⬇ | Air-Driven | Safe Area | 300 bar | 2.8 L/min |
| DP002 ⬇ | 126kW Diesel | Safe Area | Nominal: 280 bar | Peak: 350 bar | 286 L/min + 39 L/min |
| DP003 ⬇ | 126kW Diesel | Safe Area | 350 bar | 286 L/min + 39 L/min |
| DP004 ⬇ | 26kW Diesel | Safe Area | Nominal: 150 bar | Peak: 200 bar | 56 L/min |
| EP008Z ⬇ | 22kW @ 50Hz | 25.3kW @ 60Hz | ATEX Zone 2 | Nominal: 350 bar | Peak: 420 bar | 70 L/min @ 60Hz |
| EP009Z ⬇ | 22kW @ 50Hz | 25.3kW @ 60Hz | ATEX Zone 2 | Nominal: 350 bar | Peak: 420 bar | 70 L/min @ 60Hz |
| EP010 ⬇ | 5.5kW @ 50Hz | 6.6kW @ 60Hz | Safe Area | 400 bar | 6.9 L/min @ 60Hz |
| EP013 ⬇ | 15kW @ 50Hz | 17.3kW @ 60Hz | Safe Area | Nominal: 280 bar | Peak: 350 bar | 49 L/min @ 60Hz |
| EP015 ⬇ | 4kW @ 50Hz (x2) | 4.6kW @ 60Hz (x2) | Safe Area | 200 bar | 27.6 L/min @ 60Hz |
| EP016 ⬇ | 22kW @ 50Hz | 25.3kW @ 60Hz | Safe Area | Nominal: 280 bar | Peak: 350 bar | 79 L/min @ 60Hz |
| EP017 ⬇ | 22kW @ 50Hz | 25.3kW @ 60Hz | Safe Area | 210 bar | 74 L/min @ 60Hz |
| EP018 ⬇ | 55kW @ 50Hz (x2) | 63kW @ 60Hz (x2) | Safe Area | Nominal: 320 bar | Peak: 350 bar | 284 L/min @ 60Hz |
| EP019C ⬇ | 37kW @ 50Hz | 40.7kW @ 60Hz | Safe Area | Nominal: 320 bar | Peak: 350 bar | 142 L/min @ 60Hz |
| EP020 ⬇ | 7.5kW @ 50Hz | 8.6kW @ 60Hz | Safe Area | 210 bar | 24.2 L/min @ 60Hz |
| EP021 ⬇ | 7.5kW @ 50Hz | 7.5kW @ 60Hz | Safe Area | 210 bar | 24.3 L/min @ 60Hz |
| EP022Z ⬇ | 7.5kW @ 50Hz | 8.6kW @ 60Hz | ATEX Zone 1 | 250 bar | 13.8 L/min @ 60Hz |
| EP023 ⬇ | 22kW @ 50Hz | 22kW @ 60Hz | Safe Area | 255 bar | 63 L/min @ 60Hz |
| EP024 ⬇ | 22kW @ 50Hz | 22kW @ 60Hz | Safe Area | 255 bar | 63 L/min @ 60Hz |
| EP025 ⬇ | 55kW @ 50Hz | 66kW @ 60Hz | Safe Area | Nominal: 280 bar | Peak: 350 bar | 246 L/min @ 60Hz |
| EP026 ⬇ | 37kW @ 50Hz | 44.4kW @ 60Hz | Safe Area | Nominal: 250 bar | Peak: 280 bar | 172 L/min @ 60Hz |
| EP027 ⬇ | 37kW @ 50Hz | 44.4kW @ 60Hz | Safe Area | Nominal: 250 bar | Peak: 280 bar | 172 L/min @ 60Hz |
| EP028 ⬇ | 22kW @ 50Hz | 26.4kW @ 60Hz | Safe Area | Nominal: 210 bar | Peak: 220 bar | 35 L/min @ 60Hz |
| EP029 ⬇ | 30kW @ 50Hz | 36kW @ 60Hz | Safe Area | Nominal: 250 bar | Peak: 290 bar | 55 L/min @ 60Hz |
| EP030 ⬇ | 18.5kW @ 50Hz | 22.2kW @ 60Hz | Safe Area | Nominal: 280 bar | Peak: 350 bar | 49 L/min @ 60Hz |
| EP033 ⬇ | 22kW @ 50Hz | 26.4kW @ 60Hz | Safe Area | Nominal: 280 bar | Peak: 350 bar | 79 L/min @ 60Hz |
REELERS
Air-driven and electric hose and umbilical reelers, with drum capacities from 200 to 240 metres. The electric unit is rated to 7,500 psi.

An air-driven reeler from the hire fleet.
| DOWNLOADABLE SPEC PDF | POWER | ZONE | WORKING PRESSURE | MAX FLOW RATE | DRUM CAPACITY |
|---|---|---|---|---|---|
| AR010 ⬇ | Air-Driven | Safe Area | 10 bar | 310 SCFM | 240m |
| AR020 ⬇ | Air-Driven | Safe Area | 10 bar | 200 SCFM | 200m |
| AR030 ⬇ | Air-Driven | Safe Area | 10 bar | 200 SCFM | 200m |
| AR050 ⬇ | Air-Driven | Safe Area | 10 bar | 220 SCFM | 240m |
| EHR010 ⬇ | 3kW @ 50Hz | 3.6kW @ 60Hz | Safe Area | 7,500 psi | n/a | 240m |
CONTROL UNITS
Hydraulic control stands for running equipment from a safe position, including a rig skidding control stand and two diamond wire saw control stands. Every unit covers a working range rather than a single setting, from 0 to 400 bar and 0 to 320 L/min.

A diamond wire saw control stand from the hire fleet.
| DOWNLOADABLE SPEC PDF | DESCRIPTION | ZONE | WORKING PRESSURE RANGE | AVAILABLE FLOW RANGE |
|---|---|---|---|---|
| CS/RS-010 ⬇ | Rig Skidding Control Stand | n/a | 0–400 bar | 0–140 L/min |
| CS001 ⬇ | Hydraulic Control Stand | n/a | 0–400 bar | 0–140 L/min |
| CS002 ⬇ | Hydraulic Control Stand | n/a | 0–300 bar | 0–70 L/min |
| CS003 ⬇ | Hydraulic Control Stand | n/a | 0–400 bar | 0–320 L/min |
| CS004 ⬇ | Hydraulic Control Stand | n/a | 0–400 bar | 0–320 L/min |
| CS005 ⬇ | Hydraulic Control Stand | n/a | 0–250 bar | 0–45 L/min |
| CS006 ⬇ | Hydraulic Control Stand | n/a | 0–315 bar | 0–70 L/min |
| CS007 ⬇ | Hydraulic Control Stand | n/a | 0–300 bar | 0–45 L/min |
| DWCS001 ⬇ | Diamond Wire Saw Control Stand | Safe Area | 0–250 bar | 0–45 L/min |
| DWCS002 ⬇ | Diamond Wire Saw Control Stand | Safe Area | 0–250 bar | 0–45 L/min |
FILTRATION UNITS
Filter skids, filter trolleys and filter units for cleaning and conditioning hydraulic fluid, air-driven and electric, several of them ATEX Zone 2 rated. The fleet covers everything from a 3 L/min polishing unit to a 330 L/min filter skid, at pressures from 4.5 to 420 bar.

An air-driven filter unit from the hire fleet.
| DOWNLOADABLE SPEC PDF | POWER | ZONE | WORKING PRESSURE | MAX FLOW RATE |
|---|---|---|---|---|
| FS010 ⬇ | n/a | Safe Area | 14 bar | 225 L/min |
| FS020 ⬇ | n/a | Safe Area | 14 bar | 225 L/min |
| FS030 ⬇ | n/a | Safe Area | 420 bar | 330 L/min |
| FT001Z ⬇ | Air-Driven | ATEX Zone 2 | 8.6 bar | 185.5 L/min |
| FT003 ⬇ | 0.18kW @ 50Hz | 0.22kW @ 60Hz | Safe Area | 6 bar | 5 L/min |
| FU001 ⬇ | 1.02kW @ 50Hz | 1.44kW @ 60Hz | Safe Area | n/a | n/a |
| FU003 ⬇ | 0.18kW @ 50Hz | 0.22kW @ 60Hz | Safe Area | 4.5 bar | 4 L/min |
| FU004Z ⬇ | Air-Driven | ATEX Zone 2 | 4.5 bar | 4 L/min |
| FU005Z ⬇ | Air-Driven | ATEX Zone 2 | 4.5 bar | 3 L/min |
| FU006Z ⬇ | Air-Driven | ATEX Zone 2 | 8.6 bar | 185.5 L/min |
| FU008 ⬇ | Air-Driven | Safe Area | 4.5 bar | 4 L/min |
FLUSHING UNITS
A 50kW ATEX Zone 2 flushing unit, with pulse flow for shifting debris that steady flow leaves behind. 80 bar and 370 L/min, rising to 600 L/min on pulse.

The 50kW flushing unit from the hire fleet.
| DOWNLOADABLE SPEC PDF | POWER | ZONE | WORKING PRESSURE | MAX FLOW RATE |
|---|---|---|---|---|
| EF002Z ⬇ | 50kW @ 50Hz | 60kW @ 60Hz | ATEX Zone 2 | 80 bar | 370 L/min 600 L/min Pulse Flow |
TRANSFER UNITS
Air-driven fluid transfer units, both ATEX Zone 2 rated, moving up to 400 litres a minute with no electrical supply needed at the point of work.

An air-driven transfer unit from the hire fleet.
Not sure which unit you need?
Tell us what the job is, the pressure and flow you need, and whether it is a classified area. The right unit gets recommended, or built.
DECOM EQUIPMENT
Purpose-built decommissioning equipment, including our own in-house designed 500 tonne casing jack, a subsea hydraulic shear, and 290 and 390 litre subsea grabs. The casing jack has been hotshot deployed to a live well and returned inside three days. The set runs from 200 to 345 bar.
| DOWNLOADABLE SPEC PDF | DESCRIPTION | ZONE | WORKING PRESSURE | MAX FLOW RATE |
|---|---|---|---|---|
| CJ500-010 ⬇ | 500Te Casing Jack | n/a | 250 bar | n/a |
| HS010 ⬇ | Subsea Hydraulic Shear | n/a | 345 bar | 60 L/min (minimum) |
| SG290-010 ⬇ | 290L Subsea Grab | n/a | 200 bar | 25 L/min |
| SG290-020 ⬇ | 290L Subsea Grab | n/a | 200 bar | 25 L/min |
| SG390-010 ⬇ | 390L Subsea Grab | n/a | 200 bar | 25 L/min |
| SG390-020 ⬇ | 390L Subsea Grab | n/a | 200 bar | 25 L/min |
OVERBOARD EQUIPMENT
Two inch and four inch overboard chutes for taking hose and umbilical over the side without exceeding its bend radius. All five share an 850mm minimum bend radius.
| DOWNLOADABLE SPEC PDF | DESCRIPTION | ZONE | BEND RADIUS | WIDTH BETWEEN FLANGES |
|---|---|---|---|---|
| OBC2-010 ⬇ | 2″ Overboard Chute | n/a | 850mm MBR | 250mm |
| OBC2-020 ⬇ | 2″ Overboard Chute | n/a | 850mm MBR | 250mm |
| OBC2-030 ⬇ | 2″ Overboard Chute | n/a | 850mm MBR | 250mm |
| OBC4-010 ⬇ | 4″ Overboard Chute | n/a | 850mm MBR | 525mm |
| OBC4-020 ⬇ | 4″ Overboard Chute | n/a | 850mm MBR | 525mm |
SUBSEA EQUIPMENT
Diver operated subsea equipment: two divers panels, two subsea hand pumps, and a hydraulic intensifier panel that takes a 173 bar inlet up to a 690 bar outlet where a tool needs more pressure than the supply can give it.
| DOWNLOADABLE SPEC PDF | DESCRIPTION | ZONE | WORKING PRESSURE | MAX FLOW RATE |
|---|---|---|---|---|
| ITU001 ⬇ | Hydraulic Intensifier Panel | n/a | Inlet: 173 bar | Outlet: 690 bar | Inlet: 14 L/min | Outlet: 1.8 L/min |
| SDP002 ⬇ | Subsea Divers Panel | n/a | 250 bar | 60 L/min |
| SDP010 ⬇ | Subsea Divers Panel | n/a | 350 bar | 60 L/min |
| SHP010 ⬇ | Subsea Hand Pump | n/a | 400 bar | – |
| SHP020 ⬇ | Subsea Hand Pump | n/a | 400 bar | – |
MISC EQUIPMENT
Equipment that does not fit a category: 94 litre air pigs, a two inch multi-spiral hose manufacturing unit, and 42mm pipe benders.
| DOWNLOADABLE SPEC PDF | DESCRIPTION | ZONE | RANGE | DIMENSIONS (LxWxH) |
|---|---|---|---|---|
| AP010 ⬇ | 94L Air Pig | Safe Area | 10 bar | 1300mm x 950mm x 857mm |
| AP020 ⬇ | 94L Air Pig | Safe Area | 10 bar | 1300mm x 950mm x 857mm |
| HM010 ⬇ | Hose Manufacturing Unit | Safe Area | 2’’ Multi Spiral | 3000mm x 2430mm x 2650mm |
| PB001 ⬇ | Pipe Bender | n/a | 42mm | 780mm x 425mm x 980mm |
| PB002 ⬇ | Pipe Bender | n/a | 42mm | 780mm x 425mm x 980mm |
TEST EQUIPMENT
An air-driven test unit rated to 60,000 psi, for pressure testing well above normal system working pressures.
| DOWNLOADABLE SPEC PDF | POWER | ZONE | WORKING PRESSURE | MAX FLOW RATE |
|---|---|---|---|---|
| AHTU040 ⬇ | Air-Driven | Safe Area | 60,000 psi | n/a |
TEST INSTRUMENTATION
Instrumentation for proving a system rather than powering it: two flow meters, four laser particle counters covering mineral oil and water glycol, and a bottle sampler, covering 0 to 420 bar and 10 to 400 L/min.

Gauges and test instrumentation from the hire fleet.
| DOWNLOADABLE SPEC PDF | DESCRIPTION | FLUID TYPE | WORKING PRESSURE RANGE | AVAILABLE FLOW RANGE |
|---|---|---|---|---|
| BS001 ⬇ | Bottle Sampler | n/a | n/a | n/a |
| FM001 ⬇ | Flow Meter | Mineral Oil | 0–420 bar | 10–400 L/min |
| FM002 ⬇ | Flow Meter | Mineral Oil | 0–420 bar | 10–400 L/min |
| LPC001 ⬇ | Laser Particle Counter | Mineral Oil | 2–400 bar | n/a |
| LPC002 ⬇ | Laser Particle Counter | Mineral Oil | 2–400 bar | n/a |
| LPC003 ⬇ | Laser Particle Counter | Water Glycol | 2–400 bar | n/a |
| LPC004 ⬇ | Laser Particle Counter | Mineral Oil | 2–400 bar | n/a |
Common questions
Hire questions, answered
Is hire equipment available for hazardous areas?
Yes. The ITC hire fleet includes ATEX Zone 1 and ATEX Zone 2 rated units alongside safe area machines, across power units, filtration, flushing and transfer. The zone rating for every unit is listed in the tables above.
Can we see a specification before we hire?
Yes. Every unit in the ITC hire fleet has a downloadable specification sheet, linked from its part number in the tables above, giving power, zone, working pressure and flow.
What size of power unit can ITC supply?
ITC supplies from a 2.8 L/min air-driven unit up to a 126kW diesel delivering 286 L/min, with electric units from 4kW to 55kW in between, and pressures up to 400 bar nominal and 420 bar peak.
Who maintains the hire fleet?
We maintain the ITC hire fleet in-house. The same time served technicians who service client equipment look after it, and every item is fully operationally function tested before it goes out.
Can ITC deliver and support equipment offshore?
ITC technicians and engineers travel to site, including offshore, and are fully trained and registered to the necessary standards for global deployment.
What if nothing in the fleet fits the job?
We design and build equipment as well as hiring it. The ITC Combi-Reeler exists because a client needed half the deck footprint in half the usual delivery time, and it was designed, built and function tested in six weeks.
Talk to ITC about hire
Tell us what the job is and how long you need the equipment. Delivery, service and support come from ITC, the same company that built most of the fleet.
